integration-cli/TestRunModeIpcContainer: remove
1. The functionality of this test is superceded by `TestAPIIpcModeShareableAndContainer` (see integration-cli/docker_api_ipcmode_test.go). 2. This test won't work with --default-ipc-mode private. Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
This commit is contained in:
parent
4a804016ab
commit
519c06607c
1 changed files with 0 additions and 42 deletions
|
@ -2312,48 +2312,6 @@ func (s *DockerSuite) TestRunModeIpcHost(c *check.C) {
|
|||
}
|
||||
}
|
||||
|
||||
func (s *DockerSuite) TestRunModeIpcContainer(c *check.C) {
|
||||
// Not applicable on Windows as uses Unix-specific capabilities
|
||||
testRequires(c, SameHostDaemon, DaemonIsLinux)
|
||||
|
||||
out, _ := dockerCmd(c, "run", "-d", "busybox", "sh", "-c", "echo -n test > /dev/shm/test && touch /dev/mqueue/toto && top")
|
||||
|
||||
id := strings.TrimSpace(out)
|
||||
state := inspectField(c, id, "State.Running")
|
||||
if state != "true" {
|
||||
c.Fatal("Container state is 'not running'")
|
||||
}
|
||||
pid1 := inspectField(c, id, "State.Pid")
|
||||
|
||||
parentContainerIpc, err := os.Readlink(fmt.Sprintf("/proc/%s/ns/ipc", pid1))
|
||||
if err != nil {
|
||||
c.Fatal(err)
|
||||
}
|
||||
|
||||
out, _ = dockerCmd(c, "run", fmt.Sprintf("--ipc=container:%s", id), "busybox", "readlink", "/proc/self/ns/ipc")
|
||||
out = strings.Trim(out, "\n")
|
||||
if parentContainerIpc != out {
|
||||
c.Fatalf("IPC different with --ipc=container:%s %s != %s\n", id, parentContainerIpc, out)
|
||||
}
|
||||
|
||||
catOutput, _ := dockerCmd(c, "run", fmt.Sprintf("--ipc=container:%s", id), "busybox", "cat", "/dev/shm/test")
|
||||
if catOutput != "test" {
|
||||
c.Fatalf("Output of /dev/shm/test expected test but found: %s", catOutput)
|
||||
}
|
||||
|
||||
// check that /dev/mqueue is actually of mqueue type
|
||||
grepOutput, _ := dockerCmd(c, "run", fmt.Sprintf("--ipc=container:%s", id), "busybox", "grep", "/dev/mqueue", "/proc/mounts")
|
||||
if !strings.HasPrefix(grepOutput, "mqueue /dev/mqueue mqueue rw") {
|
||||
c.Fatalf("Output of 'grep /proc/mounts' expected 'mqueue /dev/mqueue mqueue rw' but found: %s", grepOutput)
|
||||
}
|
||||
|
||||
lsOutput, _ := dockerCmd(c, "run", fmt.Sprintf("--ipc=container:%s", id), "busybox", "ls", "/dev/mqueue")
|
||||
lsOutput = strings.Trim(lsOutput, "\n")
|
||||
if lsOutput != "toto" {
|
||||
c.Fatalf("Output of 'ls /dev/mqueue' expected 'toto' but found: %s", lsOutput)
|
||||
}
|
||||
}
|
||||
|
||||
func (s *DockerSuite) TestRunModeIpcContainerNotExists(c *check.C) {
|
||||
// Not applicable on Windows as uses Unix-specific capabilities
|
||||
testRequires(c, DaemonIsLinux)
|
||||
|
|