This fix tries to add an additional syslog-format of `rfc5424micro` which follows
the same as rfc5424 except that it use microsecond resolution for timestamp. The
purpose is to solve the issue raised in #21793 where log events might lose its
ordering if happens on the same second.
The timestamp field in rfc5424 is derived from rfc3339, though the maximium
resolution is limited to "TIME-SECFRAC" which is 6 (microsecond resolution).
The appropriate documentation (`docs/admin/logging/overview.md`) has been updated
to reflect the change in this fix.
This fix adds a unit test to cover the newly introduced format.
This fix fixes#21793.
Signed-off-by: Yong Tang <yong.tang.github@outlook.com>
Previously docker used obsolete rfc3164 syslog format for syslog. rfc3164 explicitly
uses semicolon as a separator between 'TAG' and 'Content' section of the log message.
Docker uses semicolon as a separator between image name and version tag.
When {{.ImageName}} was used as a tag expression and contained ":" syslog parser mistreated
"tag" part of the image name as syslog message body, which resulted in incorrect "syslogtag" been reported by syslog
daemon.
Use of rfc5424 log format partually fixes the issue as it does not use semicolon as a separator.
However using default rfc5424 syslog format itroduces backward incompatability because rsyslog template keyword %syslogtag%
is parsed differently. In rfc3164 it uses the "TAG" part reported before the "pid" part. In rfc5424 it uses "appname" part reported
before the pid part, while tag part is introduced by %msgid% part.
For more information on rsyslog configuration properties see: http://www.rsyslog.com/doc/master/configuration/properties.html
Added two options to specify logging in either rfc5424, rfc3164 format or unix format omitting hostname in order to keep backwards compatability with
previous versions.
Signed-off-by: Solganik Alexander <solganik@gmail.com>
- downcase and privatize exported variables that were unused
- make accurate an error message
- added package comments
- remove unused var ReadLogsNotSupported
- enable linter
- some spelling corrections
Signed-off-by: Morgan Bauer <mbauer@us.ibm.com>
- noplog driver pkg for '--log-driver=none' (null object pattern)
- centralized factory for log drivers (instead of case/switch)
- logging drivers registers themselves to factory upon import
(easy plug/unplug of drivers in daemon/logdrivers.go)
- daemon now doesn't start with an invalid log driver
- Name() method of loggers is actually now their cli names (made it useful)
- generalized Read() logic, made it unsupported except json-file (preserves
existing behavior)
Spotted some duplication code around processing of legacy json-file
format, didn't touch that and refactored in both places.
Signed-off-by: Ahmet Alp Balkan <ahmetalpbalkan@gmail.com>
This patch changes two things
1. Set facility to LOG_DAEMON
2. Remove ": " from tag so that the tag + pid become a single column in
the log
Signed-off-by: Darren Shepherd <darren@rancher.com>