This test has been flaky for a long time, failing with:
--- FAIL: TestInspect (12.04s)
inspect_test.go:39: timeout hit after 10s: waiting for tasks to enter run state. task failed with error: task: non-zero exit (1)
While looking through logs, noticed tasks were started, entering RUNNING stage,
and then exited, to be started again.
state.transition="STARTING->RUNNING"
...
msg="fatal task error" error="task: non-zero exit (1)"
...
state.transition="RUNNING->FAILED"
Looking for possible reasons, first considering network issues (possibly we ran
out of IP addresses or networking not cleaned up), then I spotted the issue.
The service is started with;
Command: []string{"/bin/top"},
Args: []string{"-u", "root"},
The `-u root` is not an argument for the service, but for `/bin/top`. While the
Ubuntu/Debian/GNU version `top` has a -u/-U option;
docker run --rm ubuntu:20.04 top -h 2>&1 | grep '\-u'
top -hv | -bcEHiOSs1 -d secs -n max -u|U user -p pid(s) -o field -w [cols]
The *busybox* version of top does not:
docker run --rm busybox top --help 2>&1 | grep '\-u'
So running `top -u root` would cause the task to fail;
docker run --rm busybox top -u root
top: invalid option -- u
...
echo $?
1
As a result, the service went into a crash-loop, and because the `poll.WaitOn()`
was running with a short interval, in many cases would _just_ find the RUNNING
state, perform the `service inspect`, and pass, but in other cases, it would not
be that lucky, and continue polling untill we reached the 10 seconds timeout,
and mark the test as failed.
Looking for history of this option (was it previously using a different image?) I