1
0
Fork 0
mirror of https://github.com/ruby/ruby.git synced 2022-11-09 12:17:21 -05:00
ruby--ruby/ext/tk/lib/remote-tk.rb
nagai 17743ce0a8 * ext/tk/tkutil/tkutil.c (tk_conv_args): forget to revert
thread_critical and gc_disable when raise ArgumentError.
* ext/tk/lib/remote-tk.rb: RemoteTkIp doesn't need to include TkUtil.
* ext/tk/tcltklib.c: add TclTkIp#has_mainwindow? method.
* ext/tk/lib/tk.rb: add Tk.has_mainwindow? method.
* ext/tk/lib/multi-tk.rb: add MultiTkIp#has_mainwindow? method.
* ext/tk/lib/remote-tk.rb: add RemoteTkIp#has_mainwindow? method.
* ext/tk/lib/multi-tk.rb: slave IP fail to exit itself when $SAFE==4.
* ext/tk/lib/multi-tk.rb: remove constants from MultiTkIp module to
  avoid access from external.
* ext/tk/lib/multi-tk.rb: check_root flag is ignored on slave IPs'
  mainloop.
* ext/tk/lib/multi-tk.rb: hang-up Tk.mainloop called on a slave IP
  with $SAFE==4.
* ext/tk/lib/multi-tk.rb: MultiTkIp#bg_eval_proc doesn't work
  properly.
* ext/tk/lib/multi-tk.rb: add MultiTkIp#set_cb_error(proc) and
  cb_error(exc) to log errors at callbacks on safe slave IPs.
* ext/tk/lib/multi-tk.rb: fail to get an available slave IP object
  when call Tk.mainloop in the block which is given to new_* method,
  because cannot finish initialize while the root widget is alive.
* ext/tk/lib/multi-tk.rb: fail to control a slave IP when Tk.mainloop
  runs on the IP.


git-svn-id: svn+ssh://ci.ruby-lang.org/ruby/trunk@8818 b2dd03c8-39d4-4d8f-98ff-823fe69b080e
2005-07-21 22:05:04 +00:00

488 lines
12 KiB
Ruby

#
# remote-tk.rb - supports to control remote Tk interpreters
# by Hidetoshi NAGAI <nagai@ai.kyutech.ac.jp>
if defined? MultiTkIp
fail RuntimeError, "'remote-tk' library must be required before requiring 'multi-tk'"
end
class MultiTkIp; end
class RemoteTkIp < MultiTkIp; end
class MultiTkIp
@@IP_TABLE = {}.taint unless defined?(@@IP_TABLE)
@@TK_TABLE_LIST = [].taint unless defined?(@@TK_TABLE_LIST)
def self._IP_TABLE; @@IP_TABLE; end
def self._TK_TABLE_LIST; @@TK_TABLE_LIST; end
@flag = true
def self._DEFAULT_MASTER
# work only once
if @flag
@flag = nil
@@DEFAULT_MASTER
else
nil
end
end
end
class RemoteTkIp
@@IP_TABLE = MultiTkIp._IP_TABLE unless defined?(@@IP_TABLE)
@@TK_TABLE_LIST = MultiTkIp._TK_TABLE_LIST unless defined?(@@TK_TABLE_LIST)
end
class << MultiTkIp
undef _IP_TABLE
undef _TK_TABLE_LIST
end
require 'multi-tk'
class RemoteTkIp
if defined?(@@DEFAULT_MASTER)
MultiTkIp._DEFAULT_MASTER
else
@@DEFAULT_MASTER = MultiTkIp._DEFAULT_MASTER
end
end
###############################
class << RemoteTkIp
undef new_master, new_slave, new_safe_slave
undef new_trusted_slave, new_safeTk
def new(*args, &b)
ip = __new(*args)
ip.eval_proc(&b) if b
ip
end
end
class RemoteTkIp
def initialize(remote_ip, displayof=nil, timeout=5)
if $SAFE >= 4
fail SecurityError, "cannot access another interpreter at level #{$SAFE}"
end
@interp = MultiTkIp.__getip
@interp.allow_ruby_exit = false
@appname = @interp._invoke('tk', 'appname')
@remote = remote_ip.to_s.dup.freeze
if displayof.kind_of?(TkWindow)
@displayof = displayof.path.dup.freeze
else
@displayof = nil
end
if self.deleted?
fail RuntimeError, "no Tk application named \"#{@remote}\""
end
@tk_windows = {}
@tk_table_list = []
@slave_ip_tbl = {}
@slave_ip_top = {}
@tk_windows.taint unless @tk_windows.tainted?
@tk_table_list.taint unless @tk_table_list.tainted?
@slave_ip_tbl.taint unless @slave_ip_tbl.tainted?
@slave_ip_top.taint unless @slave_ip_top.tainted?
@system = Object.new
@threadgroup = ThreadGroup.new
@safe_level = [$SAFE]
@wait_on_mainloop = [true, 0]
@cmd_queue = Queue.new
=begin
@cmd_receiver, @receiver_watchdog = _create_receiver_and_watchdog()
@threadgroup.add @cmd_receiver
@threadgroup.add @receiver_watchdog
@threadgroup.enclose
=end
@@DEFAULT_MASTER.assign_receiver_and_watchdog(self)
@@IP_TABLE[@threadgroup] = self
@@TK_TABLE_LIST.size.times{
(tbl = {}).tainted? || tbl.taint
@tk_table_list << tbl
}
@ret_val = TkVariable.new
if timeout > 0 && ! _available_check(timeout)
fail RuntimeError, "cannot create connection"
end
@ip_id = _create_connection
class << self
undef :instance_eval
end
self.freeze # defend against modification
end
def _ip_id_
@ip_id
end
def _available_check(timeout = 5)
return nil if timeout < 1
@ret_val.value = ''
@interp._invoke('send', '-async', @remote,
'send', '-async', Tk.appname,
"set #{@ret_val.id} ready")
Tk.update
if @ret_val != 'ready'
(1..(timeout*5)).each{
sleep 0.2
Tk.update
break if @ret_val == 'ready'
}
end
@ret_val.value == 'ready'
end
private :_available_check
def _create_connection
ip_id = '_' + @interp._invoke('send', @remote, <<-'EOS') + '_'
if {[catch {set _rubytk_control_ip_id_} ret] != 0} {
set _rubytk_control_ip_id_ 0
} else {
set _rubytk_control_ip_id_ [expr $ret + 1]
}
return $_rubytk_control_ip_id_
EOS
@interp._invoke('send', @remote, <<-EOS)
proc rb_out#{ip_id} args {
send #{@appname} rb_out \$args
}
EOS
ip_id
end
private :_create_connection
def _appsend(enc_mode, async, *cmds)
p ['_appsend', [@remote, @displayof], enc_mode, async, cmds] if $DEBUG
if $SAFE >= 4
fail SecurityError, "cannot send commands at level 4"
elsif $SAFE >= 1 && cmds.find{|obj| obj.tainted?}
fail SecurityError, "cannot send tainted commands at level #{$SAFE}"
end
cmds = @interp._merge_tklist(*TkUtil::_conv_args([], enc_mode, *cmds))
if @displayof
if async
@interp.__invoke('send', '-async', '-displayof', @displayof,
'--', @remote, *cmds)
else
@interp.__invoke('send', '-displayof', @displayof,
'--', @remote, *cmds)
end
else
if async
@interp.__invoke('send', '-async', '--', @remote, *cmds)
else
@interp.__invoke('send', '--', @remote, *cmds)
end
end
end
private :_appsend
def ready?(timeout=5)
if timeout < 0
fail ArgumentError, "timeout must be positive number"
end
_available_check(timeout)
end
def is_rubytk?
return false if _appsend(false, false, 'info', 'command', 'ruby') == ""
[ _appsend(false, false, 'ruby', 'RUBY_VERSION'),
_appsend(false, false, 'set', 'tk_patchLevel') ]
end
def appsend(async, *args)
if async != true && async != false && async != nil
args.unshift(async)
async = false
end
if @displayof
Tk.appsend_displayof(@remote, @displayof, async, *args)
else
Tk.appsend(@remote, async, *args)
end
end
def rb_appsend(async, *args)
if async != true && async != false && async != nil
args.unshift(async)
async = false
end
if @displayof
Tk.rb_appsend_displayof(@remote, @displayof, async, *args)
else
Tk.rb_appsend(@remote, async, *args)
end
end
def create_slave(name, safe=false)
if safe
safe_opt = ''
else
safe_opt = '-safe'
end
_appsend(false, false, "interp create #{safe_opt} -- #{name}")
end
def make_safe
fail RuntimeError, 'cannot change safe mode of the remote interpreter'
end
def safe?
_appsend(false, false, 'interp issafe')
end
def safe_base?
false
end
def allow_ruby_exit?
false
end
def allow_ruby_exit= (mode)
fail RuntimeError, 'cannot change mode of the remote interpreter'
end
def delete
_appsend(false, true, 'exit')
end
def deleted?
if @displayof
lst = @interp._invoke_without_enc('winfo', 'interps',
'-displayof', @displayof)
else
lst = @interp._invoke_without_enc('winfo', 'interps')
end
# unless @interp._split_tklist(lst).index(@remote)
unless @interp._split_tklist(lst).index(_toUTF8(@remote))
true
else
false
end
end
def has_mainwindow?
begin
inf = @interp._invoke_without_enc('info', 'command', '.')
rescue Exception
return nil
end
if !inf.kind_of?(String) || inf != '.'
false
else
true
end
end
def invalid_namespace?
false
end
def restart
fail RuntimeError, 'cannot restart the remote interpreter'
end
def __eval(str)
_appsend(false, false, str)
end
def _eval(str)
_appsend(nil, false, str)
end
def _eval_without_enc(str)
_appsend(false, false, str)
end
def _eval_with_enc(str)
_appsend(true, false, str)
end
def _invoke(*args)
_appsend(nil, false, *args)
end
def __invoke(*args)
_appsend(false, false, *args)
end
def _invoke(*args)
_appsend(nil, false, *args)
end
def _invoke_without_enc(*args)
_appsend(false, false, *args)
end
def _invoke_with_enc(*args)
_appsend(true, false, *args)
end
def _toUTF8(str, encoding=nil)
@interp._toUTF8(str, encoding)
end
def _fromUTF8(str, encoding=nil)
@interp._fromUTF8(str, encoding)
end
def _thread_vwait(var_name)
_appsend(false, 'thread_vwait', varname)
end
def _thread_tkwait(mode, target)
_appsend(false, 'thread_tkwait', mode, target)
end
def _return_value
@interp._return_value
end
def _get_variable(var_name, flag)
# ignore flag
_appsend(false, 'set', TkComm::_get_eval_string(var_name))
end
def _get_variable2(var_name, index_name, flag)
# ignore flag
_appsend(false, 'set', "#{TkComm::_get_eval_string(var_name)}(#{TkComm::_get_eval_string(index_name)})")
end
def _set_variable(var_name, value, flag)
# ignore flag
_appsend(false, 'set', TkComm::_get_eval_string(var_name), TkComm::_get_eval_string(value))
end
def _set_variable2(var_name, index_name, value, flag)
# ignore flag
_appsend(false, 'set', "#{TkComm::_get_eval_string(var_name)}(#{TkComm::_get_eval_string(index_name)})", TkComm::_get_eval_string(value))
end
def _unset_variable(var_name, flag)
# ignore flag
_appsend(false, 'unset', TkComm::_get_eval_string(var_name))
end
def _unset_variable2(var_name, index_name, flag)
# ignore flag
_appsend(false, 'unset', "#{var_name}(#{index_name})")
end
def _get_global_var(var_name)
_appsend(false, 'set', TkComm::_get_eval_string(var_name))
end
def _get_global_var2(var_name, index_name)
_appsend(false, 'set', "#{TkComm::_get_eval_string(var_name)}(#{TkComm::_get_eval_string(index_name)})")
end
def _set_global_var(var_name, value)
_appsend(false, 'set', TkComm::_get_eval_string(var_name), TkComm::_get_eval_string(value))
end
def _set_global_var2(var_name, index_name, value)
_appsend(false, 'set', "#{TkComm::_get_eval_string(var_name)}(#{TkComm::_get_eval_string(index_name)})", TkComm::_get_eval_string(value))
end
def _unset_global_var(var_name)
_appsend(false, 'unset', TkComm::_get_eval_string(var_name))
end
def _unset_global_var2(var_name, index_name)
_appsend(false, 'unset', "#{var_name}(#{index_name})")
end
def _split_tklist(str)
@interp._split_tklist(str)
end
def _merge_tklist(*args)
@interp._merge_tklist(*args)
end
def _conv_listelement(str)
@interp._conv_listelement(str)
end
def _create_console
fail RuntimeError, 'not support "_create_console" on the remote interpreter'
end
def mainloop
fail RuntimeError, 'not support "mainloop" on the remote interpreter'
end
def mainloop_watchdog
fail RuntimeError, 'not support "mainloop_watchdog" on the remote interpreter'
end
def do_one_evant(flag = nil)
fail RuntimeError, 'not support "do_one_event" on the remote interpreter'
end
def mainloop_abort_on_exception
fail RuntimeError, 'not support "mainloop_abort_on_exception" on the remote interpreter'
end
def mainloop_abort_on_exception=(mode)
fail RuntimeError, 'not support "mainloop_abort_on_exception=" on the remote interpreter'
end
def set_eventloop_tick(*args)
fail RuntimeError, 'not support "set_eventloop_tick" on the remote interpreter'
end
def get_eventloop_tick
fail RuntimeError, 'not support "get_eventloop_tick" on the remote interpreter'
end
def set_no_event_wait(*args)
fail RuntimeError, 'not support "set_no_event_wait" on the remote interpreter'
end
def get_no_event_wait
fail RuntimeError, 'not support "get_no_event_wait" on the remote interpreter'
end
def set_eventloop_weight(*args)
fail RuntimeError, 'not support "set_eventloop_weight" on the remote interpreter'
end
def get_eventloop_weight
fail RuntimeError, 'not support "get_eventloop_weight" on the remote interpreter'
end
end
class << RemoteTkIp
def mainloop(*args)
fail RuntimeError, 'not support "mainloop" on the remote interpreter'
end
def mainloop_watchdog(*args)
fail RuntimeError, 'not support "mainloop_watchdog" on the remote interpreter'
end
def do_one_evant(flag = nil)
fail RuntimeError, 'not support "do_one_event" on the remote interpreter'
end
def mainloop_abort_on_exception
fail RuntimeError, 'not support "mainloop_abort_on_exception" on the remote interpreter'
end
def mainloop_abort_on_exception=(mode)
fail RuntimeError, 'not support "mainloop_abort_on_exception=" on the remote interpreter'
end
def set_eventloop_tick(*args)
fail RuntimeError, 'not support "set_eventloop_tick" on the remote interpreter'
end
def get_eventloop_tick
fail RuntimeError, 'not support "get_eventloop_tick" on the remote interpreter'
end
def set_no_event_wait(*args)
fail RuntimeError, 'not support "set_no_event_wait" on the remote interpreter'
end
def get_no_event_wait
fail RuntimeError, 'not support "get_no_event_wait" on the remote interpreter'
end
def set_eventloop_weight(*args)
fail RuntimeError, 'not support "set_eventloop_weight" on the remote interpreter'
end
def get_eventloop_weight
fail RuntimeError, 'not support "get_eventloop_weight" on the remote interpreter'
end
end